View single post by RepairStan
 Posted: Sat Jun 7th, 2008 04:33 pm
PM Quote Reply Full Topic
RepairStan

 

Joined: Sat Jun 7th, 2008
Location: Powder Springs, GA
Posts: 5
Status: 
Offline
Thanks - I checked both switches (CN2 Terminal 1 & 5, CN2 Terminal 3 & 5 on the schematic) while manually moving the damper door, and opening and closing the oven door, and both checked out. Based on your comments and my findings, I am thinking that I have smart board problem. I also verified that the Hood TCO that is part of that circuitis functioning ( easy, because it is normally open).
Thanks for the input,