| View single post by Trying to help | |||||||||||||
| Posted: Sat Mar 29th, 2008 09:42 am |
|
||||||||||||
Trying to help
|
As far as the display fading goes, the info posted on June 22 is still your daddy. As far as the no programing, I believe your TP will have a total of 14 traces or lines on it. One by it self, and the other grouped together. The one by it self is one, the other end is 14. Prior to removing it and ohming it, make sure it is seated correctly. You never know, especially on an older unit. Cancel Lower- 5-14 Cancel Upper- 6-14 Upper Clean- 1-9 Lower Clean- 4-9 To verify you are checking them correctly, below are tests for selections you state work fine. Bake Upper- 1-7 Bake Lower - 4-7 ALL CHECKS ARE DONE WITH TP REMOVED FROM THE UNIT, PLACE IT ON A FLAT SURFACE AND HAVE SOMEONE HOLD IN THE DESIRED SELECTION WHILE YOU OHM THE TRACES. ON A GOOD PAD, YOU WILL SEE THE RESISTANCE CHANGE FROM OPEN(NOT PUSHED) TO A CLOSED READING OF APPROXIMATELY 50-100 OHMS.
____________________ If we saved YOU Beer $$ today, please make a donation to our beer fund by clicking the link below to help keep this site going. I charge $135.95 PLUS PARTS to do this repair!$! http://fixitnow.com/beerfund.htm |
||||||||||||
|
| |||||||||||||