If you do replace the board, make sure you did not cause the failure yourself.  The line relay on the board has a black and a gray wire that go to it.  If you miss-wire it and put the gray wire on the terminal marked N.O. and the Black wire on Com it can blow the board in the manner yours is.  The terminals are marked on the relay itself on the black Bakelite material.  If you miss-wire it, it will blow the board and rapid advance the timer (board power the timer motor continuously) instead of the pulse of power every 5 minutes or so it should normally receive.  I have gone on calls where it lasted a year like this, I have gone on calls where it blew it the next wash.  Check er out.  



____________________
If we saved YOU Beer $$ today, please make a donation to our beer fund by clicking the link below to help keep this site going. I charge $135.95 PLUS PARTS to do this repair!$! http://fixitnow.com/beerfund.htm