| View single post by Pegi | ||||||||||
| Posted: Thu Jun 30th, 2005 04:25 am |
|
|||||||||
Pegi
|
On the Electric Whirlpool dryers the thermo-fuse on the vent housing cuts power to the drive motor, the dryer would be dead. The thermo-fuse cuts out the heat circut <only> on the <gas> dryers, so the motor can run and exhaust any possible fumes if something happens to the gas valve. Sounds like you have not worked on as many of these as I have????
____________________ Moderator & Assistant Admin. for Servicetechhelp Associaton, Inc. http://www.servicetechhelp.com STH HELPDESK URL.... http://www.servicetechhelp.com/h2desk/ ___________________________________ For Gordon... http://serviceeveryday.com/ |
|||||||||
|
| ||||||||||