View single post by Samurai Appliance Repair Man
 Posted: Sun Dec 30th, 2007 07:38 pm
PM Quote Reply Full Topic
Samurai Appliance Repair Man



Joined: Mon Mar 21st, 2005
Location: Otterville, New Hampshire USA
Posts: 16083
Status: 
Offline
JJ 109 wrote:

From current probe-18-20 amps,   LRA -25.5 amps


Seems like good readings.



If you made this current measurement while the compressor was running (as opposed to right at start up), then these are NOT good readings. Would indicate a current path from the windings to ground has opened up and is leaking current. Do tell.