View single post by JJ 109
 Posted: Sun Dec 30th, 2007 04:13 pm
PM Quote Reply Full Topic
JJ 109

 

Joined: Tue Dec 18th, 2007
Location:  
Posts: 30
Status: 
Offline
Kenmore SxS 59658642890

Sometimes the compressor will start and run fine, then if it cycles it may or may not start again.  Usually once its unplugged and sits it will run the first time but if I unplug and try again it may or may not run.


Replaced PTC relay, no luck

Compressor readings :
    R-C: 2.2 ohms, spec sheet- 1.88=/- 10 %
   
    S-C: 8.7 ohms, spec sheet -8.7+/- 10/%



From current probe-18-20 amps,   LRA -25.5 amps


Seems like good readings.


Please help?

Last edited on Sun Dec 30th, 2007 08:13 pm by JJ 109