View single post by fixadryer
 Posted: Thu Nov 22nd, 2007 04:16 am
PM Quote Reply Full Topic
fixadryer

 

Joined: Sun Aug 21st, 2005
Location:  
Posts: 8
Status: 
Offline
happy thanksgiving! (of course)

18 year old Payne furnace has worked fine all these years.  All of a sudden - blowing cold, burners won't stay lit more than 4 seconds.  I have bought new and replaced the control board (ie ICM271C).  I have bought new and replaced the spark igniter (ie Carrier LH680512).  I have shorted LIM1 and LIM2. I have confirmed ground to the chasis.  I have replaced the batteries in the Honeywell thermostat.

Immediately after replacing the spark igniter, the burners came on for about a minute, but after that, we're back to 4 seconds, although the igniter now retains its red glow constantly when the thermostat is calling for heat.  Sometimes, it's 25 seconds blower with no flame, and 4 second blower with flame.  Other times, the blower shuts off, and flame on for four seconds.  Unfortunately, the house isn't heating up above 58 degrees. 

Any thoughts???