I have learned first hand that the problem is either the motor controller board or the diverter valve.  You MIGHT get lucky and replace the diverter valve and all will be well. The diverter valve is only 12 dollars or something small like that directly from F&P.  I was not so lucky.  I replaced the valve and I still had the same problem.  So, I had to replace the controller at 133.00.  Bam, problem fixed.