tucco, F/09 relates to an overflow condition. Here are some of the potential causes: drain hose plugged or kinked, check harnesses to drain pump, pressure switch and central control, make sure they are not loose. Check drain pump filter for junk in it, make sure inlet valve is shutting off ok and the pressure switch is ok. You can drop the bottom panel to look at the pump and filter, it's right in front. There are 3 screws on the back of the top panel, take these screws out and the top panel will slide back and then you will get a look at the central control, inlet valve and pressure switch....Unplug the machine when you get invloved with all this...Ron
|