First of all this is a great site........amazing amount of info.

F1 fault manifested after a broiler use. Now when there is power to the range and the ERC is in clock mode we get the F1. Current state is stove breaker "off" until needed and preheat to 100 degrees. (now range can be used without F1) When finished cooking....stove breaker back to "off". No other fault codes and consistant with each use.

OK; I went through all the steps. 1. Check the temp sensor. Result on three different days after cooling to room temp was 1088 to 1092 ohms. So....It's either the ERC or touchpad. 2. Unplugged the ribbon wire to the touchpad and powered up range. After 30 seconds F1. Problem solved......New ERC. Not so fast; installed a new ERC and confidently restored power to my range.........30 seconds.........F1:yikes:.

I double checked the temp sensor again and dead on 1088 ohms. I also pulled the back cover panel and looked at the wires all the way to the monster board on the back of the range.....seem OK. Is it possible that the temp sensor is junk even if the ohms are fine or is it something more sinister? Please help if anyone has any ideas.

 

Thanks.