| View single post by winenotwhine | |||||||||||||
| Posted: Tue Dec 5th, 2006 03:49 am |
|
||||||||||||
winenotwhine
|
Voltage across C and NO is 24 ac for the first four seconds when the unit fires up. It then drops to zero and doesn't move. There's a click at about 15 seconds after start-up--the ignitor. Only confusing thing is that soon after I hear the click I smell gas. Gas, click but no fire. Could we have a dead ignitor? Back to the pressuer switch, I made the assumption that the voltage test was a test to be done indepenantly. That is, without reference to a manometer reading. If I'm wrong, let me know--I'll re-run referencing pressure readings. Thanks--alot, the image came across with no fuzz--easy to interpret.
|
||||||||||||
|
| |||||||||||||