Usually on a ERC motorized unit like I believe this one is, the sensor will be bad. Usually the specs are far out enough to not let the door unlock, but not far enough out of calibration to cause a fault code. Start by ohming the sensor, if it comes in considerably higher then the 1100 room temp standard, that's your boy. If not, we will have to check for power out of the ERC to the motor and see which one is FUBAR 