View single post by AccApp
 Posted: Wed Jul 19th, 2006 01:24 pm
Full Topic

Joined: Sat Jun 3rd, 2006
Location: Eatontown, New Jersey USA
Posts: 1788
Most evaporator leaks are so small you would never find them with a soap bubble test. Yes, you probably had a piece of ice where the liguid refrigerant enters the evap but it has gone away if refrigerant was added. If the compressor is running , there should be frost all along the evaporator. When the compressor stops, the ice melts.

Which pan was full?

"When you have eliminated all which is impossible, then whatever remains, however improbable, must be the truth." Sir Arthur Conan Doyle.