| View single post by Southern | |||||||||||||
| Posted: Mon Mar 20th, 2006 12:17 am |
|
||||||||||||
Southern
|
It is normal for the drain valve to be open for C:07 & C:08. Once the drain valve opens during C:06 it remains open until the end of C:08. You might want to verify the remaining pressure switches (Suds Detect, Level 1 & Overflow) for 0 ohms. The illustration is on page 5-6. Also check for continuity between the pressure switch contacts and the terminals on the CCU to eliminate a bad connection as the problem.
|
||||||||||||
|
| |||||||||||||