That means the DW is on that GFI circuit. Though not "plugged" in to it, it is wired into that circuit. One thing you can try is to kill power to the unit and use a test cord to run the unit on a non GFI outlet. If it works, then the problem is more then likely in your GFI circuit. If it does not, then we will want to start making some cks to the unit to see if we have a s shorted or grounded component. Since your model starts each cycle with a drain purge, I would start by ohming out your motor and making sure your connections are good and tight at your wire nuts in your DW conduit box behind the kick plate.      