Service bulletin:  Servicers were asked to change the Control Board in the Dispenser any time they service a New Generation SXS Refrigerator with Serial # before LA14799999, (Only if not previously replaced). This can be identified by a # 1 marked by a permanent marker, under the drip tray in the bottom of the dispenser. Some Servicers are replacing both the Power Board and the Control Board adding cost to repairs. Solution: Only Change the Control Board.  Refer to your model. See note! The problem with the Control Board is the Dispenser Lights operate erratically. The Power Board only needs to be replaced if you do not have power to the Dispenser, it doesn’t operate, or the lights are not on.