View single post by jabko
 Posted: Fri Oct 14th, 2005 01:42 am
PM Quote Reply Full Topic
jabko



Joined: Thu Oct 6th, 2005
Location: BLACKWOOD, New Jersey USA
Posts: 87
Status: 
Offline
Sounds feasable if there is a shorted than required defrost time, also had I/M leak down to the same area causing a frost build up, some of these fans also became noisy on there own, and if not replaced may cause the pc board to fail, due to the position GE installed the fan water was able to migrate down the shaft through the bearing causing a motor failue, if you find a bad evap. motor might also need the board, let me know if anyone needs the dianogisis progam information, the models with the LED display can be tested from the touch pads, if it is a decoder model (knobs) you need the parts listed on the spec sheet, there is a access plug under the freezer hinge to plug it in.................John