View single post by kingbob151
 Posted: Wed Nov 3rd, 2010 05:18 pm
PM Quote Reply Full Topic
kingbob151

 

Joined: Wed Oct 13th, 2010
Location:  
Posts: 3
Status: 
Offline
Kdog, there is plenty of secondary air.

RegUS_PatOff the new vent is a strait pipe out the wall behind the dryer. Into the garage. for testing purpose's theres no vent cap and the garage door is wide open.

Tronicsmasta I confirmed the correct orafice spud, although bosch did have conflicting burner specs for lp. one said 15K, one said 18K.

I did find that the L1 and neutral were reversed at the main control. A bad harness. After correcting that, the unit will run down to 0:00 back to 0:01 for an additional 10 min. when set to a 20 min timed dry. When asked about this, bosch said thats the way it is. The retail is going to swap the pair(washer and dryer) for the 500 series. I'll let you know if I get the same results