Those are normal fluctuations for your unit depending on how often it was doing it and how long it would stay that way. From the looks of your coils in the picture that you posted you have a problem. Its not normal for the bottom 1/3 of the cols to be frosted as much as shown in that picture. Looks like your fan may have been bad from the get go.

The only thing that will make the coils look as yours did with really heavy frost on bottom and none on top is a gas leak ( which isn't the case because the unit was producing below 0 temps.) An air leak (door seal or dispenser flapper) or a whacky or broken fan) did you replace the evap. Thermistor or the freezer thermistor?