| View single post by Pegi | ||||||||||
| Posted: Sat Aug 20th, 2005 05:34 pm |
|
|||||||||
Pegi
|
Might want to start with this. No water detected entering machine or Pressure switch trip not detected. If after 30 seconds the control does not detect water entering machine and then valves will be turned off and the error code will be displayed. Or If the control has turned the water valves on and after 8 minutes the flow meter has detected 10.5 gallons of water passing through it, but has not detected the pressure switch trip, the valves will be turned off and the error code will flash. Press PAUSE/CANCEL twice to clear the display.