m_ouwerkerk
|
Here are the trouble shooting steps for F3: F3 Water temperature sensed at greater than 85°C ( 185°F) 1 Is the incoming water temperature greater than 85°C (185°F) Y: Adjust the incoming water temperature. N: Go to Question 2 2 Is the element on all the time? Y: Replace the electronic controller N: Go to Question 3 3 Are the wiring and connections from the controller to the element all okay? Y: Go to Question 4 N: Repair or replace wiring harness or wiring connections 4 Are there any signs of moisture around the temperature sensor? Y: Locate and repair source of leak N: Go to Question 5 5 Is the resistance of the temperature sensor correct? Y: Go to Question 6 N: Replace heater plate assembly 6 Does the machine fault again if run through a test cycle? Y: Go to Question 1 N: No fault found
|
||||||||||||
|
| |||||||||||||