RegUS_PatOff wrote: check those voltages again... should read 120VAC on L1 P1  (connected directly to L2 Line voltage)

Wiring Diagram # 318046743 REV A

Also check voltage accross P4 to P7 with either bake or broil selected (all wires connected), this relay is a common failure for this board and is in both the bake & broil ckts, (Symptoms - Call for Bake - Bake element does not heat, Call for Broil, Broil element does not heat).