darcypa wrote: ...
Disconected Y-2 from the side NOT directly connected to the EOC, Called for Bake at 350,

Reading 123 VAC at each of the bake element terminals

Bake P2 = 6 VAC
Broil P3 = 0 VAC
L1 P1 = 5.9 VAC
L2 OUT P4 = 0 VAC
L2 In P7 = 6.1

Do the Cooktop Burners work OK ?

> Reading 123 VAC at each of the bake element terminals

OK, looks good.. some of the Relays on the EOC are good.....

> Bake P2 = 6 VAC
> Broil P3 = 0 VAC
> L1 P1 = 5.9 VAC
> L2 OUT P4 = 0 VAC
> L2 In P7 = 6.1

check those voltages again... should read 120VAC on L1 P1  (connected directly to L2 Line voltage)

Wiring Diagram # 318046743 REV A