View single post by darcypa
 Posted: Wed May 20th, 2009 05:49 am
PM Quote Reply Full Topic
darcypa

 

Joined: Mon May 18th, 2009
Location:  
Posts: 6
Status: 
Offline
Good day,

     Wiring Diagram # 318046743 REV A

Disconected Y-2 from the side NOT directly connected to the EOC, Called for Bake at 350,

Reading 123 VAC at each of the bake element terminals

Bake P2 = 6 VAC
Broil P3 = 0 VAC
L1 P1 = 5.9 VAC
L2 OUT P4 = 0 VAC
L2 In P7 = 6.1 VAC

Disconnected Y-2 from the side DIRECTLY connected to the EOC, Called for Bake at 350,

Reading 0 VAC at each of the bake element terminals

Bake P2 = 6 VAC
Broil P3 = 0 VAC
L1 P1 = 6 VAC
L2 OUT P4 = 0 VAC
L2 In P7 = 6.2 VAC

Disconnected BL-2 from the side NOT directly connected to the EOC, Called for Broil HI,

reading 123VAC at each side of the Broil element terminals

Bake P2 = 0 VAC
Broil P3 = 6.9 VAC
L1 P1 = 6.2 VAC
L2 OUT P4 = 0 VAC
L2 In P7 = 6.4 VAC


Disconnected BL-2 from the side DIRECTLY connected to the EOC, Called for Broil HI,

reading 0 VAC at each side of the Broil element terminals

Bake P2 = 0 VAC
Broil P3 = 6.3 VAC
L1 P1 = 6.3 VAC
L2 OUT P4 = 0 VAC
L2 In P7 = 6.5 VAC

Note - I have attached a zip file with a short piece of audio of a sound I hear when I plug the stove in.


Whats Next?


Attachment: VN 00003.zip (Downloaded 3 times)