| View single post by Greewater_man | |||||||||||||
| Posted: Tue Jan 6th, 2009 03:30 am |
|
||||||||||||
Greewater_man
|
I have a Rheem Furnace, about 15-20 years old. It was running fine and all of a sudden it I don't have any heat. The sequence is as follows. 1. Put the thermostat in hold temp and set for 75 degrees Which I know if warmer than the house. There is three feet of snow outside! 2. Fan comes on. There is a little click then after about about 15-20 seconds, another click and the igniter begins to glow. It glows real good and continues for a brief while and then turns off. I never heard any gas valve open or something to that effect. I checked the propane tank and it is at 80%. There is a large silver capacitor in the box that has some slight corrosion on the tabs. I cleaned it well and replaced the wire connectors. What does this capacitor do? Is it for the fan motor?
|
||||||||||||
|
| |||||||||||||